{"id":6198,"date":"2026-11-20T13:39:59","date_gmt":"2026-11-20T05:39:59","guid":{"rendered":"https:\/\/matismart.com\/?p=6198"},"modified":"2026-11-20T13:40:03","modified_gmt":"2026-11-20T05:40:03","slug":"rs485-power-quality-meter","status":"publish","type":"post","link":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/","title":{"rendered":"RS485 Power Quality Meter Integration for BMS and SCADA"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">An <strong>RS485 power quality meter<\/strong> can deliver electrical data to a BMS, SCADA, PLC, or energy management system over a simple serial network. However, successful integration requires more than connecting two communication wires.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The installer must plan the bus topology, device addresses, baud rate, parity, termination, grounding, polling, and register mapping. A problem in any one of these areas can create missing values or unstable communication.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is an RS485 Power Quality Meter?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An RS485 power quality meter combines electrical measurement with an RS485 physical interface. In many projects, the device uses Modbus RTU over that interface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, RS485 and Modbus are not the same thing. RS485 defines the electrical communication layer. Modbus defines how devices exchange requests, responses, and data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/www.modbus.org\/file\/secure\/modbusoverserial.pdf\" target=\"_blank\" rel=\"noopener\">Modbus Serial Line Protocol and Implementation Guide<\/a> describes new serial implementations using an EIA\/TIA-485 interface and a trunk network. Therefore, the physical bus and the application protocol must both match.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Typical RS485 Power Quality Meter Architecture<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A common architecture is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Power quality meters \u2192 RS485 Modbus RTU bus \u2192 PLC, BMS controller, SCADA server, or gateway \u2192 software<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First, each meter measures the connected electrical circuit. Next, the controller polls selected registers. Finally, the upper-level software stores, trends, and displays the data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A gateway may be useful when the upstream system needs Ethernet, Modbus TCP, MQTT, cloud connectivity, network separation, or local buffering.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Use a Bus Topology, Not a Star<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">RS485 normally works best as a daisy-chain or trunk. Devices connect along the main cable, while branch stubs remain short.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By contrast, a large star topology can create reflections and unstable communication. Therefore, avoid running a separate long cable from every meter back to one central point unless the network design uses suitable active equipment.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Item<\/th><th class=\"has-text-align-left\" data-align=\"left\">What to Confirm<\/th><th class=\"has-text-align-left\" data-align=\"left\">Common Problem<\/th><\/tr><\/thead><tbody><tr><td>Topology<\/td><td>Trunk or daisy-chain route<\/td><td>Long star branches<\/td><\/tr><tr><td>Address<\/td><td>Unique ID for every meter<\/td><td>Duplicate addresses<\/td><\/tr><tr><td>Serial settings<\/td><td>Baud rate, parity, stop bits<\/td><td>Devices use different settings<\/td><\/tr><tr><td>Polarity<\/td><td>Consistent A\/B connection<\/td><td>Reversed pair<\/td><\/tr><tr><td>Termination<\/td><td>Applied at the correct bus ends<\/td><td>Missing or excessive termination<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Match Every Serial Setting<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">All devices on one bus must use compatible serial settings. Confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Device address<\/li>\n\n\n\n<li>Baud rate<\/li>\n\n\n\n<li>Parity<\/li>\n\n\n\n<li>Data bits<\/li>\n\n\n\n<li>Stop bits<\/li>\n\n\n\n<li>Response timeout<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For example, a meter set to 9600 baud with even parity will not communicate correctly with a controller using a different format. In addition, two meters cannot share the same address on one bus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Plan Polling Around Useful Data<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A power quality meter may expose hundreds of registers. However, the BMS does not need to poll every value every second.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, group the data by purpose:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fast operating values: voltage, current, power, and frequency<\/li>\n\n\n\n<li>Medium-speed values: demand, power factor, THD, and unbalance<\/li>\n\n\n\n<li>Slow values: energy totals, maximum values, and configuration<\/li>\n\n\n\n<li>Event data: alarms, dips, swells, and records where supported<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This approach reduces network load and improves response time. It also makes the BMS point list easier to maintain.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Confirm the Register Map Before Ordering<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The product brochure may say Modbus RTU, but the integrator still needs the complete register map. It should define:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Register addresses and function codes<\/li>\n\n\n\n<li>Data types and register length<\/li>\n\n\n\n<li>Signed or unsigned values<\/li>\n\n\n\n<li>Byte and word order<\/li>\n\n\n\n<li>Scaling factors and engineering units<\/li>\n\n\n\n<li>Read-only and writable registers<\/li>\n\n\n\n<li>Alarm and event access<\/li>\n\n\n\n<li>Firmware or protocol version<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">RS485 Power Quality Meter Options from Matismart<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/matismart.com\/product\/three-phase-multi-functional-power-meter-pem3000\/\">Matismart PEM3000<\/a> supports RS485 Modbus RTU for BMS and SCADA integration. It provides three-phase electrical measurement, demand, unbalance, and harmonics up to the 50th order.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/matismart.com\/product\/smart-power-quality-analyzer-pem5000\/\">PEM5000 fixed-panel meter<\/a> adds deeper event, waveform, storage, and display functions. It supports both RS485 Modbus RTU and Ethernet Modbus TCP.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For several feeders, the <a href=\"https:\/\/matismart.com\/product\/multi-circuit-multi-functional-power-meter-mpm4000\/\">MPM4000<\/a> combines multi-circuit measurement with RS485 and Ethernet communication.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before final selection, confirm the exact registers, sensor inputs, wiring system, communication options, and firmware version required by the project.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">RS485 Commissioning Checklist<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Verify voltage and current phase mapping<\/li>\n\n\n\n<li>Confirm CT ratio and sensor direction<\/li>\n\n\n\n<li>Assign a unique Modbus address<\/li>\n\n\n\n<li>Match baud rate, parity, and stop bits<\/li>\n\n\n\n<li>Check RS485 polarity<\/li>\n\n\n\n<li>Verify termination and cable shielding<\/li>\n\n\n\n<li>Read one known register<\/li>\n\n\n\n<li>Confirm scaling and byte order<\/li>\n\n\n\n<li>Compare readings with the meter display<\/li>\n\n\n\n<li>Document the final point list and settings<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Is RS485 the same as Modbus RTU?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. RS485 is an electrical interface. Modbus RTU is a communication protocol that commonly runs over RS485.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How many power quality meters can connect to one RS485 bus?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The practical number depends on the transceivers, cable, distance, baud rate, polling load, and network design. Follow the device and controller limits rather than assuming one universal number.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does an RS485 network need termination resistors?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Often yes, especially on longer or faster networks. Place termination according to the approved bus design and device documentation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can an RS485 power quality meter connect directly to a BMS?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes, if the BMS supports Modbus RTU and can map the meter registers. Otherwise, the project may need a gateway or controller.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why does the meter display correct values while the BMS shows wrong values?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common causes include an incorrect register address, data type, byte order, scaling factor, CT ratio, or phase mapping.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Treat Communication as Part of the Metering Design<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An RS485 power quality meter is only useful when the upper-level system receives accurate and stable data. Plan the physical bus, serial settings, point list, and polling strategy before commissioning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Share the meter quantity, cable distance, required data, BMS protocol, and system architecture with Matismart. Our team can help review the device and integration route.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>An RS485 connection is reliable only when the physical bus, serial settings and Modbus register map are planned together. This guide explains the main integration checks for power quality meters.<\/p>\n","protected":false},"author":2,"featured_media":6199,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[15],"tags":[186,187,188,189,190],"class_list":["post-6198","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-insights","tag-rs485-power-quality-meter","tag-modbus-rtu-power-quality-meter","tag-bms-power-quality-meter","tag-scada-power-meter","tag-rs485-meter-wiring"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>RS485 Power Quality Meter Integration Guide<\/title>\n<meta name=\"description\" content=\"Learn how to connect an RS485 power quality meter to BMS or SCADA, including topology, addressing, baud rate, termination and register mapping.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RS485 Power Quality Meter Integration Guide\" \/>\n<meta property=\"og:description\" content=\"Learn how to connect an RS485 power quality meter to BMS or SCADA, including topology, addressing, baud rate, termination and register mapping.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\" \/>\n<meta property=\"og:site_name\" content=\"Matismart\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-20T05:39:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-20T05:40:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/matismart.com\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"513\" \/>\n\t<meta property=\"og:image:height\" content=\"321\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Grace\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Grace\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\"},\"author\":{\"name\":\"Grace\",\"@id\":\"https:\/\/matismart.com\/ar\/#\/schema\/person\/5ec96d805b82ba34f5127a86bfca6011\"},\"headline\":\"RS485 Power Quality Meter Integration for BMS and SCADA\",\"datePublished\":\"2026-11-20T05:39:59+00:00\",\"dateModified\":\"2026-11-20T05:40:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\"},\"wordCount\":912,\"image\":{\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp\",\"keywords\":[\"RS485 power quality meter\",\"Modbus RTU power quality meter\",\"BMS power quality meter\",\"SCADA power meter\",\"RS485 meter wiring\"],\"articleSection\":[\"Insights\"],\"inLanguage\":\"ar_AR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\",\"url\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\",\"name\":\"RS485 Power Quality Meter Integration Guide\",\"isPartOf\":{\"@id\":\"https:\/\/matismart.com\/ar\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp\",\"datePublished\":\"2026-11-20T05:39:59+00:00\",\"dateModified\":\"2026-11-20T05:40:03+00:00\",\"author\":{\"@id\":\"https:\/\/matismart.com\/ar\/#\/schema\/person\/5ec96d805b82ba34f5127a86bfca6011\"},\"description\":\"Learn how to connect an RS485 power quality meter to BMS or SCADA, including topology, addressing, baud rate, termination and register mapping.\",\"breadcrumb\":{\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#breadcrumb\"},\"inLanguage\":\"ar_AR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar_AR\",\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage\",\"url\":\"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp\",\"contentUrl\":\"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp\",\"width\":513,\"height\":321},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/matismart.com\/ar\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Insights\",\"item\":\"https:\/\/matismart.com\/ar\/category\/insights\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"RS485 Power Quality Meter Integration for BMS and SCADA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/matismart.com\/ar\/#website\",\"url\":\"https:\/\/matismart.com\/ar\/\",\"name\":\"Matismart\",\"description\":\"Smarter Electric, Safer Efficiency\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/matismart.com\/ar\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar_AR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/matismart.com\/ar\/#\/schema\/person\/5ec96d805b82ba34f5127a86bfca6011\",\"name\":\"Grace\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar_AR\",\"@id\":\"https:\/\/matismart.com\/ar\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/55b5dd94b7aadd919f6e95fbc62e19408bdbdea6be465a63046c8a02adf5e54d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/55b5dd94b7aadd919f6e95fbc62e19408bdbdea6be465a63046c8a02adf5e54d?s=96&d=mm&r=g\",\"caption\":\"Grace\"},\"url\":\"https:\/\/matismart.com\/ar\/ar\/author\/grace\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RS485 Power Quality Meter Integration Guide","description":"Learn how to connect an RS485 power quality meter to BMS or SCADA, including topology, addressing, baud rate, termination and register mapping.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/","og_locale":"ar_AR","og_type":"article","og_title":"RS485 Power Quality Meter Integration Guide","og_description":"Learn how to connect an RS485 power quality meter to BMS or SCADA, including topology, addressing, baud rate, termination and register mapping.","og_url":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/","og_site_name":"Matismart","article_published_time":"2026-11-20T05:39:59+00:00","article_modified_time":"2026-11-20T05:40:03+00:00","og_image":[{"width":513,"height":321,"url":"https:\/\/matismart.com\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp","type":"image\/webp"}],"author":"Grace","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Grace","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#article","isPartOf":{"@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/"},"author":{"name":"Grace","@id":"https:\/\/matismart.com\/ar\/#\/schema\/person\/5ec96d805b82ba34f5127a86bfca6011"},"headline":"RS485 Power Quality Meter Integration for BMS and SCADA","datePublished":"2026-11-20T05:39:59+00:00","dateModified":"2026-11-20T05:40:03+00:00","mainEntityOfPage":{"@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/"},"wordCount":912,"image":{"@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp","keywords":["RS485 power quality meter","Modbus RTU power quality meter","BMS power quality meter","SCADA power meter","RS485 meter wiring"],"articleSection":["Insights"],"inLanguage":"ar_AR"},{"@type":"WebPage","@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/","url":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/","name":"RS485 Power Quality Meter Integration Guide","isPartOf":{"@id":"https:\/\/matismart.com\/ar\/#website"},"primaryImageOfPage":{"@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage"},"image":{"@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp","datePublished":"2026-11-20T05:39:59+00:00","dateModified":"2026-11-20T05:40:03+00:00","author":{"@id":"https:\/\/matismart.com\/ar\/#\/schema\/person\/5ec96d805b82ba34f5127a86bfca6011"},"description":"Learn how to connect an RS485 power quality meter to BMS or SCADA, including topology, addressing, baud rate, termination and register mapping.","breadcrumb":{"@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#breadcrumb"},"inLanguage":"ar_AR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/"]}]},{"@type":"ImageObject","inLanguage":"ar_AR","@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#primaryimage","url":"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp","contentUrl":"https:\/\/matismart.com\/ar\/wp-content\/uploads\/2026\/11\/rs485-power-quality-meter-integration.webp","width":513,"height":321},{"@type":"BreadcrumbList","@id":"https:\/\/matismart.com\/ar\/rs485-power-quality-meter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/matismart.com\/ar\/"},{"@type":"ListItem","position":2,"name":"Insights","item":"https:\/\/matismart.com\/ar\/category\/insights\/"},{"@type":"ListItem","position":3,"name":"RS485 Power Quality Meter Integration for BMS and SCADA"}]},{"@type":"WebSite","@id":"https:\/\/matismart.com\/ar\/#website","url":"https:\/\/matismart.com\/ar\/","name":"Matismart","description":"Smarter Electric, Safer Efficiency","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/matismart.com\/ar\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar_AR"},{"@type":"Person","@id":"https:\/\/matismart.com\/ar\/#\/schema\/person\/5ec96d805b82ba34f5127a86bfca6011","name":"Grace","image":{"@type":"ImageObject","inLanguage":"ar_AR","@id":"https:\/\/matismart.com\/ar\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/55b5dd94b7aadd919f6e95fbc62e19408bdbdea6be465a63046c8a02adf5e54d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/55b5dd94b7aadd919f6e95fbc62e19408bdbdea6be465a63046c8a02adf5e54d?s=96&d=mm&r=g","caption":"Grace"},"url":"https:\/\/matismart.com\/ar\/ar\/author\/grace\/"}]}},"_links":{"self":[{"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/posts\/6198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/comments?post=6198"}],"version-history":[{"count":1,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/posts\/6198\/revisions"}],"predecessor-version":[{"id":6200,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/posts\/6198\/revisions\/6200"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/media\/6199"}],"wp:attachment":[{"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/media?parent=6198"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/categories?post=6198"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/matismart.com\/ar\/wp-json\/wp\/v2\/tags?post=6198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}